Exterior Wall Construction coating leveling paint characteristics
Nippon Exterior Wall Construction leveling paint can be used to directly scrape and renovate the walls of old walls such as paints, mosaics, tiles, and stone. In the process of use, it can be nearly smoothed by simple smoothing. The effect can completely reduce the unevenness of the wall, and at the same time, it has good elasticity, resists cracks, overcomes the wall damage caused by the temperature difference, and has strong adhesion when using the leveling paint. The leveling process needs to be constructed by experts. Processing will be more complete.
Exterior Wall Construction leveling coating construction technology
Most people are familiar with Nippon interior paint, but the flattening coating construction process is completely unclear. When Nippon exterior wall leveling coating is applied, the ratio is very important. The ratio of powder to water is 10:3 -4, pour the water into the container, then slowly add the powder, then stir well with a power agitator. Nippon exterior wall leveling paint is recommended to be used within 3 hours after the completion of the blending. If the temperature is higher, it is recommended to use it within 2 hours, so as to ensure the quality of the project effectively.
Nippon Exterior Wall Construction leveling paint can be used to directly scrape and renovate the walls of old walls such as paints, mosaics, tiles, and stone. In the process of use, it can be nearly smoothed by simple smoothing. The effect can completely reduce the unevenness of the wall, and at the same time, it has good elasticity, resists cracks, overcomes the wall damage caused by the temperature difference, and has strong adhesion when using the leveling paint. The leveling process needs to be constructed by experts. Processing will be more complete.
Exterior Wall Construction leveling coating construction technology
Most people are familiar with Nippon interior paint, but the flattening coating construction process is completely unclear. When Nippon exterior wall leveling coating is applied, the ratio is very important. The ratio of powder to water is 10:3 -4, pour the water into the container, then slowly add the powder, then stir well with a power agitator. Nippon exterior wall leveling paint is recommended to be used within 3 hours after the completion of the blending. If the temperature is higher, it is recommended to use it within 2 hours, so as to ensure the quality of the project effectively.
Services
Exterior wall construction leveling coating - precautions
Although the construction of Nippon exterior wall leveling coating is simple and quick, there are also some precautions. The Nippon exterior wall leveling coating should be stored in a cool and dry place. The storage temperature is preferably 0-35°C early and the construction temperature is 5-40°C. The relative humidity of the air is <80%. Avoid raining within 12 hours after the completion of construction. Nippon exterior wall construction leveling coatings contain alkaline before the upper wall is dry. Because the leveling paint should use a series of complex reactions such as ash calcium and water and carbon dioxide to improve its own strength, calcium hydroxide will be produced during use, which usually lasts for 5-7 days before disappearing. Not good, it will give the builder a burning sensation, and must pay attention to the characteristics of the leveling paint during construction.
Although the construction of Nippon exterior wall leveling coating is simple and quick, there are also some precautions. The Nippon exterior wall leveling coating should be stored in a cool and dry place. The storage temperature is preferably 0-35°C early and the construction temperature is 5-40°C. The relative humidity of the air is <80%. Avoid raining within 12 hours after the completion of construction. Nippon exterior wall construction leveling coatings contain alkaline before the upper wall is dry. Because the leveling paint should use a series of complex reactions such as ash calcium and water and carbon dioxide to improve its own strength, calcium hydroxide will be produced during use, which usually lasts for 5-7 days before disappearing. Not good, it will give the builder a burning sensation, and must pay attention to the characteristics of the leveling paint during construction.